gsphelp  Afterburner maps format

<< Click to Display Table of Contents >>

Navigation:  GSP components > Component off-design effects > Component maps > Map formats >

gsphelp  Afterburner maps format

Previous pageReturn to chapter overviewNext page

Afterburner (3 maps of 1 in 1 out)

For an afterburner a set of 3 maps is used to determine the combustion efficiency.

Map Type Indicator Map Title

↓                  ↓

99                 F100PW200 Afterburner combustion efficiency map / as function of relative FAR

Reynolds correction data

Reynolds: RNI=0.100 f=0.950 RNI=1.000 f=1.000

Table Content Keyword

FARrel - ETArel

Table data

0.0390   0.9400

0.0585   0.9887

0.0732   1.0193

etc.

 

Map Type Indicator Map Title

↓                  ↓

99                 F100PW200 Afterburner combustion efficiency map / as function of relative FAR

Reynolds correction data

Reynolds: RNI=0.100 f=1.000 RNI=1.000 f=1.000

Table Content Keyword

FARrel - ETArel

Table data

0.0390   0.9400

0.0585   0.9887

0.0732   1.0193

etc.

 

Map Type Indicator Map Title

↓                  ↓

99                 Afterburner combustion efficiency Mach Correction map

Reynolds correction data

Reynolds: RNI=0.100 f=1.000 RNI=1.000 f=1.000

Table Content Keyword

dMachrel - dETArel

Table data

1.000   -0.000

1.071   -0.013

1.190   -0.041

etc.

 

 

Map Type Indicator Map Title

↓                  ↓

99                 Afterburner combustion efficiency Pressure Correction map

Reynolds correction data

Reynolds: RNI=0.100 f=1.000 RNI=1.000 f=1.000

Table Content Keyword

dPrel - dETArel

Table data

0.220    -0.1420

0.2267   -0.1250

0.2500   -0.1000

etc.